← Back to library
article 2022 8 pages

An Index of Non-Linear HRV as a Proxy of the Aerobic Threshold Based on Blood Lactate Concentration in Elite Triathletes

Bruce Rogers, Sander Berk, Thomas Gronwald

Journal
Sports
DOI
10.3390/sports10020025
Population
elite triathletes
View on DOI ↗

Abstract

non-linear index of heart rate (HR) variability (HRV) known as alpha1 of Detrended Fluctuation Analysis (DFA a1) has been shown to change with increasing exercise intensity, crossing a value of 0.75 at the aerobic threshold (AT) in recreational runners de ning a HRV threshold (HRVT). Since large volumes of low-intensity training below the AT is recommended for many elite endurance athletes, con rmation of this relationship in this speci c group would be advantageous for the purposes of training intensity distribution monitoring. Nine elite triathletes (7 male, 2 female) attended a training camp for diagnostic purposes. Lactate testing was performed with an incremental cycling ramp test to exhaustion for the determination of the rst lactate threshold based on the log–log calculation method (LT1). Concurrent measurements of cardiac beta-to-beat intervals were performed to determine the HRVT. Mean LT1 HR of all 9 participants was 155.8 bpm ( 7.0) vs. HRVT HR of 153.7 bpm ( 10.1) (p= 0.52). Mean LT1 cycling power was 252.3

cycling ramp test to exhaustion for the determination of the rst lactate threshold based on the log–log calculation method (LT1). Concurrent measurements of cardiac beta-to-beat intervals were performed to determine the HRVT. Mean LT1 HR of all 9 participants was 155.8 bpm ( 7.0) vs. HRVT HR of 153.7 bpm ( 10.1) (p= 0.52). Mean LT1 cycling power was 252.3 W ( 48.1) vs. HRVT power of 247.0 W ( 53.6) (p= 0.17). Bland–Altman analysis showed mean differences of 1.7 bpm and 5.3 W with limits of agreement (LOA) 13.3 to 16.7 bpm and 15.1 to 25.6 W for HR and cycling power, respectively. The DFA a1-based HRVT closely agreed with the LT1 in a group of elite triathletes. Since large volumes of low-intensity exercise are recommended for successful endurance performance, the fractal correlation properties of HRV show promise as a low-cost, non-invasive option to that of lactate testing for identi cation of AT-related training boundaries. Keywords: heart rate variability; lactate threshold; DFA a1; training intensity distribution; polarized training 1. Introduction Knowledge of exercise intensity boundaries is important for guidance in athletic training and diagnostics. Various models of training intensity distribution have been proposed (polarized, threshold and pyramidal) but all share one aspect in common, that the majority of training is to be performed in a low-intensity zone range [1]. In the typical three- zone model, the upper low-intensity limit is felt to be regarded as the aerobic threshold (AT), represented by either the rst lactate (LT1) or ventilatory threshold (VT1) [2]. Although an incremental ramp test with gas exchange monitoring can be performed to determine the VT1, many athletic training centers utilize progressive constant cycling power intervals with lactate testing to determine the AT using the LT1. Although, on rst glance, this would seem a simple endeavor, several issues make the concept more complex. Importantly, there does not appear to be universal agreement on what concept de nes the LT1 [3]. Some investigators have used a xed value of 2 mmol/L, while others use a xed value above Sports2022,10, 25.

rst glance, this would seem a simple endeavor, several issues make the concept more complex. Importantly, there does not appear to be universal agreement on what concept de nes the LT1 [3]. Some investigators have used a xed value of 2 mmol/L, while others use a xed value above Sports2022,10, 25.

Sports2022,10, 25 2 of 8 baseline of 0.5 or 1 mmol/L. Other options include logarithmic plotting of lactate against cycling power or heart rate (HR) [4]. This could lead to variable results of a training boundary obtained by one measure or another. Besides the confusion surrounding test de nition, lactate testing is invasive, relatively costly and generally requires additional personnel to perform the test while the athlete is exercising. Therefore, alternate means of determining the AT have been evaluated over the years including modalities related to various heart rate variability (HRV) indexes[5–7]. However, despite initial appeal, general use for the purpose of low-intensity training guidance has not occurred for various reasons [8,9]. Recently, HRV monitoring during the exercise session has received a resurgence in attention as a method of measuring the AT [8]. In a group of recreational runners, the AT was found to closely match that of a HRV threshold (HRVT) derived from a non-linear HRV index of fractal correlation properties determined by alpha1 of Detrended Fluctuation Analysis (DFA a1) [9]. As exercise intensity rises, the DFA a1 declines from values near 1, which represent the well-correlated fractal behavior of the cardiac beat-to-beat pattern, passing a value of 0.75 at the AT, then reaching uncorrelated, random behavior at intensities past the AT. Potential advantages of this approach to estimating the AT include cost, easy availability of HR monitoring devices and its non-invasive nature. However, since initial validation of this approach was performed by comparing the HRVT to the AT as represented by the VT1 derived from gas exchange during treadmill running, potential agreement with an alternative method such as the LT1 evaluated during an incremental cycling stage ramp is unknown and should be addressed. In order to show that the HRVT is a robust, reliable surrogate for the AT, evaluation in certain population subsets would also be helpful. For instance, this marker may be applicable in a group possessing average tness abilities but loses validity with elite endurance athletes. Since the elite endurance athlete typically performs large amounts of training in the low-intensity zone, validation of the HRVT principle

the HRVT is a robust, reliable surrogate for the AT, evaluation in certain population subsets would also be helpful. For instance, this marker may be applicable in a group possessing average tness abilities but loses validity with elite endurance athletes. Since the elite endurance athlete typically performs large amounts of training in the low-intensity zone, validation of the HRVT principle in these individuals would be especially bene cial. Recent observational analysis has shown that the volume of low-intensity training performed by competitive long-distance runners [10] as well as the high training volume performed by recreational half marathon runners [11] is related to their future performance. Therefore, given the need for accurate delineation of the low-intensity boundary in elite athletes for training and testing purposes, the intent of this report is to explore the relationship of the DFA a1-based HRVT with that of the LT1, obtained at an athletic team assessment camp. 2. Methods 2.1. Participants Nine elite triathletes (7 male, 2 female) of various countries of origin were recruited from a triathlon assessment training camp. Current competition category ranged between national and international levels. Average age was 24 years ( 4), body weight 69 kg ( 9), height 175 cm ( 10), weekly training volume 20 h ( 3) and . V O2MAX67 mL/kg/min ( 7). This study was conducted during routine diagnostic procedures in a training camp and no additional equipment was used for data collection and no further procedures were performed. Physiologic testing was performed at the beginning of the camp. Athletes had not performed any recent high-intensity exercise and were deemed well rested by the coaching staff. All participants were informed about the study procedures and objectives. They provided written informed consent according to the ethical guidelines in accordance with the institutional review board and the guidelines of the Helsinki World Medical Association Declaration. 2.2. Exercise Testing Protocol An incremental cycling stage test until voluntary exhaustion was performed with a Cyclus2 ergometer (RBM elektronik-automation GmbH, Leipzig, Germany) with a freely chosen cadence between 80 and 90 rpm. The test protocol for men consisted of a starting cycling

in accordance with the institutional review board and the guidelines of the Helsinki World Medical Association Declaration. 2.2. Exercise Testing Protocol An incremental cycling stage test until voluntary exhaustion was performed with a Cyclus2 ergometer (RBM elektronik-automation GmbH, Leipzig, Germany) with a freely chosen cadence between 80 and 90 rpm. The test protocol for men consisted of a starting cycling power of 90 W (watts), with an incremental rise of 30 W every 3 min. For women,

Sports2022,10, 25 3 of 8 the starting cycling power was 75 W, with an incremental rise every 3 min of 25 W. Machine calibration was performed in accordance with manufacturer recommendations. Ambient temperature (14 to 17 C), altitude of 45 m and meal timing were similar for all participants. Both caffeine and alcohol consumption were avoided for 24 h pretesting. There was no tobacco usage in any participant. 2.3. Lactate Testing All lactate samples were measured with the Lactate Pro2 (Arkray KDK, Kyoto, Japan) between 30 and 40 s before the end of each ramp stage, except the last sample, which was taken directly after completion of the test (10–15 s after cessation). Determination of the rst lactate threshold was performed using automated testing software [4], using logarithmic plotting of lactate vs. either cycling power or HR. 2.4. RR Measurements and Calculation of DFA a1-Derived HRVT A Polar H10 (Polar Electro Oy, Kempele, Finland) HR monitoring device (HRM) was used to detect RR intervals in 7 individuals, a Pioneer HRM (Pioneer Electronics, Torrance, CA, USA) Inc was used in one individual and a Garmin HRM (Garmin Inc, Olathe, KS, USA) in another due to individual preferences. All RR data were recorded with a Garmin 530 cycling computer (Garmin Inc., Olathe, KS, USA) and then imported into Kubios HRV Software Version 3.4.3 (Biosignal Analysis and Medical Imaging Group, Department of Physics, University of Kuopio, Kuopio, Finland). Kubios preprocessing settings were set to the default values including the RR detrending method which was kept at “Smoothness priors” (Lambda = 500) [12]. DFA a1 window width was set to 4 n 16 beats. The RR series was then corrected by the Kubios “automatic method” and relevant HRV parameters exported as text les for further analysis. Artifact levels measured by Kubios HRV were below 5%. This limit was previously shown to have minimal effect on the HRVT [13]. DFA a1 was calculated from the RR data series using 2 min time windows with repeat computation every 5 s throughout the test (time-varying method—window width = 2 min, grid interval = 5 s). Two-minute time

further analysis. Artifact levels measured by Kubios HRV were below 5%. This limit was previously shown to have minimal effect on the HRVT [13]. DFA a1 was calculated from the RR data series using 2 min time windows with repeat computation every 5 s throughout the test (time-varying method—window width = 2 min, grid interval = 5 s). Two-minute time windowing was chosen to achieve a suf cient minimal beat count [14]. For the detection of HRVT, a DFA a1 value of 0.75 was selected based on previous study in recreational athletes [9]. This value is also the midpoint between a fractal, well-correlated behavior of the HR time series of 1.0 (seen with very light exercise) and an uncorrelated value of 0.5 which represents random behavior (seen with high-intensity exercise) [8]. Plotting of DFA a1 vs. HR was then performed, generally showing a stable area above 1.0 at low work rates, a rapid, near linear drop reaching below 0.5 at higher intensity, then plateauing without major change. The procedure used to indicate at what level of cycling intensity as HR the DFA a1 would cross a value of 0.75 has been detailed previously [9]. Cycling power at DFA a1 = 0.75 (cycling power at HRVT) was calculated from the 180 s average cycling power preceding the time DFA a1 reached 0.75. 2.5. Statistics Statistical analysis was performed for: HR and cycling power at LT1 derived from lactate testing; HR and cycling power at HRVT derived from DFA a1. Standard statistical methods were used for the calculation of means and standard deviations (SD). Normal distribution of data was checked by Shapiro–Wilk's test. The agreement with LT1 param- eters was assessed using linear regression, Pearson's r correlation coef cient, intraclass correlation coef cient (ICC), Lin's concordance correlation coef cient (CCC), standard error of estimate (SEE), and Bland–Altman plots with limits of agreement [15]. All Bland–Altman plots were assessed for proportional bias. The size of Pearson's r correlations was evaluated as follows: 0.3 r < 0.5 low; 0.6 r < 0.8 moderate; and r 0.8 high, [16] The paired t-test was used for

cient (ICC), Lin's concordance correlation coef cient (CCC), standard error of estimate (SEE), and Bland–Altman plots with limits of agreement [15]. All Bland–Altman plots were assessed for proportional bias. The size of Pearson's r correlations was evaluated as follows: 0.3 r < 0.5 low; 0.6 r < 0.8 moderate; and r 0.8 high, [16] The paired t-test was used for comparison of LT1 vs. HRVT for both cycling power and HR. For all tests, the statistical signi cance was accepted asp 0.05. Analysis was performed using Microsoft Excel 365 with Real Statistics Resource Pack (Release 6.8) and Analyse-it software (Version 5.66).

Sports2022,10, 25 4 of 8 3. Results Lactate Threshold and HRVT Comparison Mean LT1 HR for all 9 participants was 155.8 bpm ( 7.0) vs. HRVT HR of 153.7 bpm ( 10.1) (p= 0.52). Mean LT1 cycling power was 252.3 W ( 48.1) vs. HRVT cycling power of 247.0 W ( 53.6) (p= 0.17). Regression plots are shown in Figure power comparisons. Bland–Altman analyses for comparisons of HR and cycling power are shown in Figure. Mean differences were 1.7 bpm and 5.3 W with LOA of 13.3 and 16.7 bpm for HR and of 15.1 and 25.6 W for cycling power; no proportional bias was found (HR: r = 0.38p= 0.31; cycling power: r = 0.55p= 0.11). All data were normally distributed (All W > 0.90,p> 0.31). ICC (1,1) between LT1 HR and HRVT HR was 0.69 (95% con dence limits 0.14 to 0.92) and was 0.98 (95% con dence limits 0.91 to 0.99) for cycling power. CCC between LT1 HR and HRVT HR was 0.66 (95% con dence limits 0.11 to 0.90) and was 0.98 (95% con dence limits 0.92 to 0.99) for cycling power. Figure 1. Regression plots for all participant data. (A): Values of LT1 vs. HRVT for HR in bpm. (B): Values of LT1 vs. HRVT for cycling power in W. Bisection lines in light gray. SEE: standard error of estimate; r: Pearson's r. Points symbolized by X represent female participants.

Sports2022,10, 25 5 of 8 Figure 2. Bland-Altman Plot of LT1 vs. HRVT for all participants. (A): Values of LT1 vs. HRVT for HR in bpm. (B): Values of LT1 vs. HRVT for cycling power in W. Center line in each plot represents the mean difference between each paired value, the top and bottom lines are 1.96 standard deviations from the mean difference. Points symbolized by X represent female participants. 4. Discussion This study aimed to con rm the association of the DFA a1-based HRVT with that of the LT1, an established marker of the AT [3] in a demographic consisting of elite male and female triathletes using a cycling stage ramp test. The results show clear relationships between the LT1 calculated by the log–log method and HRVT for both HR and cycling power. This was supported by linear regression, with Pearson's r of 0.77 and 0.98 for HR and cycling power, respectively. There was no difference between mean values of LT1 and HRVT by paired t testing. Bland–Altman analysis showed minimal mean differences that were felt to be acceptable for the purpose of exercise and training prescription. Although a previous report found a good concordance between the HRVT and VT1 assessed by gas exchange, that study was performed in recreational runners using a treadmill test with research grade ECG monitoring [9]. Given the potential value of an alternate non-invasive marker for the AT, further investigation into varied user populations, alternate recording devices and exercise modalities are warranted before widespread usage. The participants evaluated here did represent an elite class of triathlete including several national team members. Weekly training volumes and . V O2MAXmeasurements were in agreement with this and well above typical recreational levels [17]. Since elite endurance sport participants are frequently the subjects of training intensity distribution research, positive con rmation of the HRVT equivalence to the LT1 could be helpful with non-invasive zone boundary identi cation and enforcement. The underlying mechanism for DFA a1 behavior during exercise appears to be related to the antagonistic behavior of the sympathetic and parasympathetic branches of the auto- nomic nervous system

participants are frequently the subjects of training intensity distribution research, positive con rmation of the HRVT equivalence to the LT1 could be helpful with non-invasive zone boundary identi cation and enforcement. The underlying mechanism for DFA a1 behavior during exercise appears to be related to the antagonistic behavior of the sympathetic and parasympathetic branches of the auto- nomic nervous system on the sinoatrial node [18] as well as other potential factors [19]. As work intensity rises there is a withdrawal of the parasympathetic component and enhance- ment of the sympathetic component with the net result being that of a decline of DFA a1 as well as other HRV parameters. However, as opposed to conventional HRV indexes that rely on a nadir to determine the AT, DFA a1 appears to pass a speci c dimensionless value of 0.75. Therefore, asymptotic curve interpretation and calibration to metabolic parameters such as a lactate or ventilatory threshold is unnecessary. This has obvious advantages in both retrospective HRV analysis and real-time monitoring of exercise demands. The reasoning behind choosing a DFA a1 value of 0.75 as a focus for VT1 transition was based on several factors [8,9]. Inspection of prior DFA a1 incremental ramp studies appeared to indicate that the aerobic threshold was situated near this area [8]. In addition, this value represents the midpoint between correlated fractal patterns seen with low intensity loads (1.0) and uncorrelated random patterns seen at intensity domains past the aerobic

Description

This study explores the relationship between heart rate variability and lactate threshold in elite triathletes.