Abstract
introduction of carbon ber plate shoes has triggered a plethora of world records in running, which has encouraged shoe industries to produce novel shoe designs to enhance running performance, including shoes containing conductor elements or grounding
Medicine, University of Rome Foro Italico, 00135 Rome, Italy 8 European Federation of Sports Medicine Associations (EFSMA), 1007 Lausanne, Switzerland *Correspondence: y.pitsiladis@brighton.ac.uk Abstract: The introduction of carbon ber plate shoes has triggered a plethora of world records in running, which has encouraged shoe industries to produce novel shoe designs to enhance running performance, including shoes containing conductor elements or grounding shoes (GS), which could potentially reduce the energy cost of running. The aim of this study was to examine the physiological and perceptual responses of athletes subjected to grounding shoes during running. Ten elite runners were recruited. Firstly, the athletes performed an incremental running test for VO 2max and anaerobic threshold (AT) determination, and were familiarized with the two shoe conditions (traditional training shoe (TTS) and GS, the latter containing a conductor element under the insole). One week apart, athletes performed running economy tests (20 min run at 80% of the AT) on a 400 m dirt track, with shoe conditions randomized. VO 2, heart rate, lactate, and perceived fatigue were registered throughout the experiment. No differences in any of the physiological or perceptual variables were identi ed between shoe conditions, with an equal running economy in both TTS and GS (51.1 4.2 vs. 50.9 5.1 mL kg 1 min 1 , respectively). Our results suggest that a grounding stimulus does not improve the energy cost of running, or the physiological/perceptual responses of elite athletes. Keywords: earthing; environmental physiology; running performance; running economy; shoe technology; grounding 1. Introduction During the past ve years, shoe designs have experienced a great technological revolution, which has been accompanied by a plethora of world records in all long- distance running events (i.e., from 5000 m to marathons, in both male and female athletes). Joyner et al., recently suggested that the factors potentially explaining the recent records in long-distance running are the physiological and training factors, in addition to shoe technology and drafting [1]. However, the abrupt drop in world records across all distances since 2017 suggests that shoe technology has a major contribution when compared to the other factors (i.e., training methods, the physiology
et al., recently suggested that the factors potentially explaining the recent records in long-distance running are the physiological and training factors, in addition to shoe technology and drafting [1]. However, the abrupt drop in world records across all distances since 2017 suggests that shoe technology has a major contribution when compared to the other factors (i.e., training methods, the physiology of athletes, and drafting are factors that have not substantially changed in the last 5 years) [2]. Int. J. Environ. Res. Public Health2022,19, 1317.
Int. J. Environ. Res. Public Health2022,19, 1317 2 of 10 The most popular shoe technology for road running includes a carbon ber plate (CFP) within the sole, a light and highly reactive foam, and a stack up to 40 mm in thickness. This technology has been shown to reduce the energy cost of running during a xed exercise intensity (traditionally between 14 and 18 km h 1 ) by approximately 4%, when compared to non-CFP shoes [35]. This improved running economy (RE) seems to be elicited by an increase in energy return caused by the action of passive elastic recoil, which in turn increases stride length and contact times, reduces step frequencies, and slightly increases the peak forces upon ground contact, when compared to non-CFP shoes [3,6,7]. The great popularity and effectiveness of CFP shoes has encouraged the shoe industry to explore new forms of shoe designs to optimize both health and performance during running. The implementation of grounding in humans purports to take advantage of the prolonged contact between an individual and the ground, and the potential transmission of energy between the two. Previous research states that the direct contact of humans with the earth or using a metal conductor changes the electric potential on the surface of the body, as well as within the entire human organism [8]. While the etiology of this potential effect is dif cult to explain from a biophysiological perspective, previous ndings have shown that the direct contact of an individual with the ground may reduce in ammatory processes, mood, pain, and stress at rest [911] and during exercise [8,9], with some studies suggesting that grounding technology may have a medical application. For example, previous research has suggested that the implementation of grounding is bene cial for mood, and may be especially bene cial in cases of depression, anxiety, stress, and trauma [11,12]. In relation to the existing research on grounding and exercise, an informative pilot study examined the effects of grounding on muscle physiology in response to exercise- induced muscle damage, and observed faster muscle recovery times under the grounding condition compared to
bene cial for mood, and may be especially bene cial in cases of depression, anxiety, stress, and trauma [11,12]. In relation to the existing research on grounding and exercise, an informative pilot study examined the effects of grounding on muscle physiology in response to exercise- induced muscle damage, and observed faster muscle recovery times under the grounding condition compared to the placebo [13]. The same group performed a more comprehensive follow-up study [14], observing that grounding signi cantly reduced creatine kinase (CK) levels 24 h post-exercise when compared to the placebo, suggesting that grounding may reduce acute muscular damage post-exercise. Following these early studies on grounding and muscle damage, a further study focused on the impact that this technology may have during aerobic exercise [8]. Sokal et al. claimed that the indirect contact of cyclists with the ground (through a metal conductor) while exercising elicited an increase in the electrical potential of the body when compared to those in the control group (not grounded). This study further reported that the observed increase in electrical potential with was accompanied by a greater decrease in blood urea concentrations during and after a 30 min cycling test at 50% of VO2max, indicating, according to the authors, a decreased physiological stress [8]. While these previous studies showed a bene t of grounding on the muscle recovery and physiological stress of healthy subjects in response to different modes of exercise (i.e., resistance training and cycling), the impact of this technology while running is unknown. Given the imminent introduction of grounding technology in running shoes, and the absence of rigorous scienti c evidence of its effects, adding conductor elements within the shoe and employing a well-controlled experimental design, would allow for the assessment of any putative effects of this technology (i.e., grounding technology in running shoes) during running. This is especially important given the recent controversy that novel shoe technologies are negatively impacting the integrity and fairness within sport [2,15]. A recent critical review [2] highlighted how novel shoe designs are revolutionizing the world of sport, as numerous National, European, World, and Olympic records have been
effects of this technology (i.e., grounding technology in running shoes) during running. This is especially important given the recent controversy that novel shoe technologies are negatively impacting the integrity and fairness within sport [2,15]. A recent critical review [2] highlighted how novel shoe designs are revolutionizing the world of sport, as numerous National, European, World, and Olympic records have been broken over an extraordinarily short time period (i.e., since the introduction of CFP shoes). In addition to this controversy, there is a lack of well-controlled and rigorous studies in the eld that focus on the impact of shoe designs on running performance [2], which makes the true performance bene ts of certain shoe technologies dif cult to determine. Considering the reduced physiological stress and muscle damage witnessed in subjects while performing other physical activities (i.e., strength exercises and cycling), it is impor- tant to examine the impact of grounding on the physiological and perceptual responses to
Int. J. Environ. Res. Public Health2022,19, 1317 3 of 10 running, especially considering the interest of shoe companies in incorporating grounding technology into running shoes, and the potential fairness/integrity issues that may result if a performance bene t is demonstrated. Therefore, the main aim of the present study was to compare the RE and physiological stress of well-trained runners while running in either grounding shoes (GS) or traditional training shoes (TTS). 2. Materials and Methods 2.1. Participants Ten highly-trained male runners (age = 27 7 years; weight = 64.6 6 kg; height = 176.3 5.4 cm) were recruited for the present study. Upon recruitment, all subjects received and signed an informed consent form in order to participate in the study. Subjects were required to meet the following inclusion criteria: (1) to train a minimum of 50 km week 1 , (2) to have a personal best under 35:00 min:s in 10 km or 17:30 min:s in 5 km, (3) to be healthy and without any musculoskeletal injury. 2.2. Procedures The present study design required runners to visit either the laboratory or the track on two occasions, both separated by a period of 7 days to avoid any residual fatigue. Visit 1 included a VO2max test, ventilatory threshold determination, and shoe familiarization in the laboratory; Visit 2 included 20 min RE tests at 80% of the anaerobic threshold, on a 400 m dirt track, with the order of the two shoe conditions randomized (Figure). A dirt track was selected over a traditional synthetic PU rubber track to avoid any material interference between the ground and the athlete. The present study was approved by the Ethics Committee of Aragon (CEICA, num. 17/2021). 2.3. Shoe Conditions Two shoe conditions were tested: the traditional training shoe (TTS) and the grounding shoe (GS), with these being visually identical as shown in Figure. Shoes with grounding potential contained a conductor element around the insole, and aimed to diminish the physiological stress experienced by the athlete during running as they run in closer contact with the ground. The insulation and thermal permeability of the shoes were considered
training shoe (TTS) and the grounding shoe (GS), with these being visually identical as shown in Figure. Shoes with grounding potential contained a conductor element around the insole, and aimed to diminish the physiological stress experienced by the athlete during running as they run in closer contact with the ground. The insulation and thermal permeability of the shoes were considered similar, given that the same material was used for both experimental and non-experimental shoes, with the exception of the conductor element. Both uppers consisted of the same knitted textile, produced and supplied at the same time for both types of shoe (Figure). The GS upper included a textile webbing containing yarn that encouraged electrical charge to ow through the material. The material was stitched into the collar area, and ran through the midsole to connect with the rubber on the outsole that contacts the ground. The TTS outsole included conventional rubber, while the GS outsole included rubber that encouraged the ow of electrical charge. The manufacturers labelled the shoes with a number in red or blue according to the two shoe conditions, and this setting was used by the research team to keep the study design double-blinded (See Figure). Additionally, as each athlete may have become subjectively biased during the familiarization trial, all blue/red labels were obscured with tape in Visit 2. All athletes had their own pair of shoes for each shoe condition. 2.4. Visit 1. Maximal Oxygen Uptake and Ventilatory Threshold Determination On the rst day, athletes were subjected to a skin temperature test and a SARS-CoV-2 antigen test, in order to participate in this study. Upon testing negative, informed consent was signed by all participants, and medical history and pre-participation screening was also completed. The laboratory assessments performed during the rst day included: Anthropometric and body composition assessments. The parameters measured were as follows: weight, height, height from sitting position, foot length, calf circumference and fold, and thigh circumference and fold. Percent body fat, muscle mass, and bone mass were assessed with a DXA scan (Hologic Corp., Bedford, MA, USA). Body fat, body water, and
performed during the rst day included: Anthropometric and body composition assessments. The parameters measured were as follows: weight, height, height from sitting position, foot length, calf circumference and fold, and thigh circumference and fold. Percent body fat, muscle mass, and bone mass were assessed with a DXA scan (Hologic Corp., Bedford, MA, USA). Body fat, body water, and
Int. J. Environ. Res. Public Health2022,19, 1317 4 of 10 muscle mass were also assessed via bioimpedance (TANITA BC 780-S MA, Tanita Corp., Tokyo, Japan).Int. J. Environ. Res. Public Health 2022, 19, x FOR PEER REVIEW 4 of 11 Figure 1. Image of the right grounding shoe (A) and traditional training shoe (B) for one of the elite athletes. 2.3. Shoe Conditions Two shoe conditions were tested: the traditional training shoe (TTS) and the grounding shoe (GS), with these being visually identical as shown in Figure 1. Shoes with grounding potential contained a conductor element around the insole, and aimed to diminish the physiological stress experienced by the athlete during running as they run in closer contact with the ground. The insulation and thermal permeability of the shoes were considered similar, given that the same material was used for both experimental and non-experimental shoes, with the exception of the conductor element. Both uppers consisted of the same knitted textile, produced and supplied at the same time for both types of shoe (Figure 1). The GS upper included a textile webbing containing yarn that encouraged electrical charge to flow through the material. The material was stitched into the collar area, and ran through the midsole to connect with the rubber on the outsole that contacts the ground. The TTS outsole included conventional rubber, while the GS outsole included rubber that encouraged the flow of electrical charge. The manufacturers labelled the shoes with a number in red or blue according to the two shoe conditions, and this setting was used by the research team to keep the study design double-blinded (See Figure 1). Additionally, as each athlete may have become subjectively biased during the familiarization trial, all blue/red labels were obscured with tape in Visit 2. All athletes had their own pair of shoes for each shoe condition. Figure 1. Image of the right grounding shoe (A) and traditional training shoe (B) for one of the elite athletes. Maximal aerobic capacity test. All subjects were previously familiarized with VO2max testing. Prior to the VO2max test, subjects laid down for 5 min, and
tape in Visit 2. All athletes had their own pair of shoes for each shoe condition. Figure 1. Image of the right grounding shoe (A) and traditional training shoe (B) for one of the elite athletes. Maximal aerobic capacity test. All subjects were previously familiarized with VO2max testing. Prior to the VO2max test, subjects laid down for 5 min, and resting electrocar- diograms and blood pressure tests were performed and assessed by experienced medical doctors to ensure athletes did not have any cardiological issues. Participants breathed through a low dead space mask, with air sampled at 60 mL min 1 . Before each test, two-point calibrations of the gas sensors were completed, using a known gas mixture (16% O2and 5% CO2) and ambient air. Ventilatory volume was calibrated using a 3 L ( 0.4%) syringe. Firstly, subjects performed a self-paced warm-up, and prior to the com- mencement of the test, subjects were instrumented with a portable metabolic analyzer (Cosmed K5, Cosmed Srl, Rome, Italy) and a heart rate device (Polar H10, Polar Electro, Kempele, Finland). A short-ramp incremental protocol was used (i.e., 1316 min) as this has been shown to be the most appropriate assessment for identifying individual physiological events in well-trained runners [1618]. The protocol consisted of a 3 min run at 10 km h 1 and a 1% gradient on a treadmill (h/p/cosmos, NussdorfTraunstein, Germany), followed by increases of 1 km h 1 min 1 until volitional exhaustion. Heart rate was monitored throughout the test, and overall perception of effort (RPE) and speci c RPE for the legs were registered immediately after the test. This test enabled the determination of VO2max (de ned as the highest 30 s mean values obtained during the test) and individual anaerobic threshold (IAT), determined through visual assessment conducted by two experienced exercise physiologists. Each individual speed for subsequent shoe trials were determined
Int. J. Environ. Res. Public Health2022,19, 1317 5 of 10 at the 80% of the IAT velocity. This VO2max test involved the subjects' preferred shoe, and served to objectively quantify individual running speed for subsequent RE trials (avoiding the impact of the slow component of oxygen uptake given the repeated square-wave design of the RE tests on the second visit). Visit 1 also involved the familiarization of the different running shoes during a light, 5 min run with each pair of shoes, in preparation for Visit 2. 2.5. Visit 2. Running Economy Tests During the second visit, indices of performance, with particular focus on RE, were assessed for each shoe condition, determined on a 400 m dirt track. Air temperature and humidity were recorded at the beginning and end of the experimental sessions using a portable meteorological station, and all trials were performed either in the early morning or late evening to avoid extreme environmental conditions. Participants breathed through a low dead space mask, with air sampled at 60 mL min 1 . Before each subject's rst trial, the portable metabolic analyzer was calibrated following the calibration procedures aforementioned. The shoe conditions were randomly assigned, and both runners and assessors were blinded to the shoe condition. Brand new socks were used for each RE trial to avoid excessive humidity within the shoe, as this could impact grounding effect. Body mass was measured before and after each test. Each runner warmed up for 15 min with their preferred training shoes prior to being equipped with the portable metabolic analyzer. Pre-trial blood lactate was measured from a single drop of whole blood from the ngertip using a lactate meter (Lactate Pro 2, Arkray Europe, B.V., Amstelveen, the Netherlands), and pre-trial heart rate and RPE were also collected. Athletes performed two 20 min exercise bouts at 80% of their IAT velocity for each shoe condition, with a 20 min rest in between (Figure). The duration of this RE protocol was longer than traditional RE tests (46 min) used in previous studies examining shoe designs [35]. The reason for this was to allow for
Description
Grounding shoes do not improve running performance in elite athletes.